Conditions for the Conversion of Gypsum to Hydrogen Sulfide in MSW Landfills SCS Engineers

 

Hydrogen sulfide (H2S) is often identified as a potential culprit of odors and nuisance complaints near municipal solid waste (MSW) landfills. Some base their complaints on information found on the Internet as fact. As experts, let’s start by saying data from other landfills or pulled from an AI browser summary online will not provide accurate answers. H2S concentrations vary widely and are unique to individual landfills.

 

How is H2S generated in an MSW landfill, and why do concentrations vary?
Calcium sulfate (CaSO4•2H2O, aka gypsum), the primary ingredient in wallboard (aka drywall), can be biologically converted to H2S under select and somewhat rare conditions. Specifically, seven conditions are required for the biodegradation of gypsum to H2S. See (Gypsum Association, Industry Technical Paper: Treatment and Disposal of Gypsum Board Waste (Jan. 1991); Gypsum Association, Treatment and Disposal of Gypsum Board Waste, Part II, Technical Paper (Mar. 1992).

  1. Liquid Water (i.e., saturated waste with free liquids)
  2. Source of Soluble Sulfate
  3. Sulfate-reducing Bacteria
  4. Organic Material
  5. Anoxic Environment
  6. Appropriate pH Range
  7. Appropriate Temperature Range

 

Condition 1 – Liquid Water. The biological conversion of sulfate to H2S occurs in the aqueous phase—i.e., sufficient free liquids must be present, and sulfates must dissolve into the free liquids. Modern landfills with leachate collection systems may experience intermittent perched and discrete zones of saturation within the waste mass, particularly following periods of extended precipitation. Low-permeability confining layers (e.g., clay or clay-like soil used for intermediate cover) may temporarily trap water/leachate in discrete pockets within the landfill.

Condition 2 – Source of Soluble Sulfate. Gypsum, having the chemical formula CaSO4•2H2O, is a source of soluble sulfate. Gypsum sources include wallboard (aka drywall), flue gas desulfurization (FGD) material from coal-fired power plants, and some industrial wastes. Sulfates and sulfur compounds can also be present in lower concentrations in other waste streams, depending on what the MSW landfill accepts.

Condition 3 – Sulfate-reducing Bacteria. Sulfate-Reducing Bacteria (“SRB”) use dissolved sulfate as an electron acceptor in the oxidation of carbon. Primary SRB include Desulfovibrio and Desulfotomaculum. These SRBs, as well as many other bacteria, are commonly present in MSW landfills. However, the presence of SRB within a landfill may not be ubiquitous, and may be limited to regions where the other required conditions favor their existence and survival.

Condition 4 – Organic Material. SRBs use organic material as a food source to multiply and degrade sulfate to H2S. Carbon serves as a source of energy for the bacteria. Typical MSW has a high organic content due to a wide variety of organic materials such as wood, paper, cardboard, food, vegetative waste, and fabrics. Many communities with recycling programs help divert these waste materials for reuse and recycling.

Condition 5 – Anoxic Environment. SRBs thrive under anoxic (without oxygen) conditions. The presence of oxygen can kill SRBs. While anoxic conditions are typically not present in areas where MSW was recently disposed, they are typical in portions of MSW landfills where organic wastes have been present for at least a few months and decompose to produce methane and carbon dioxide.

Condition 6 – Appropriate pH Range. SRB reduction of sulfate to H2S is reportedly optimum within a pH range of about 7 to 8, and does not occur outside a pH range of about 4 to 9. The pH range within a typical MSW landfill falls within this activity range.

Condition 7 – Appropriate Temperature Range. SRB reproduction and H2S generation are reportedly optimum within a range of about 30 °C to 38 °C (86 °F to 100 °F). Many MSW landfills are within or a little above this optimum range. Studies of SRB in geologic environmental settings found reduced activity above about 60 °C (140 °F), and no activity above about 80 °C (176 °F). Similarly, SRB activity ceases in freezing conditions.

 

In summary,  although the necessary conditions for H2S generation are likely intermittently present within some discrete pockets within many MSW landfills, the conditions are not likely ubiquitous throughout the waste. MSW landfill conditions and waste composition are typically highly heterogeneous with respect to both location within the landfill and time. Thus, there are zones within landfills where many, but not all of the seven required conditions are present, and H2S generation does not occur. For example, there are undoubtedly many regions within landfills where free liquids (i.e., saturated conditions) are not present and, therefore, SRB conversion of sulfates to H2S does not occur, despite the presence of the other six conditions.

Similarly, a landfill may have pockets where bulk sulfate-containing waste has been disposed of but where the internal portion of the pocket is not exposed to moisture, organics, or SRB—each a necessary condition for converting sulfate to H2S.

Considering these seven conditions and heterogeneous landfill conditions, there are too many variables to provide a reliable and defendable quantitative model for H2S generation at all MSW landfills.

 

Monitoring and Treating Landfill H2S Conditions
We invite you to use our free resource library to learn more about how monitoring and data collection can protect your workers and the surrounding environment.

 

Jeff MarshallAbout the Author: Jeff Marshall, PE, is a Vice President of SCS Engineers and our National Expert on Emerging Contaminants (e.g., PFAS) and Innovative Technologies. He has over four decades of experience emphasizing environmental chemistry (e.g., hydrogen sulfide generation at MSW landfills), environmental permitting and compliance (e.g., fumigation facilities), hazardous materials/waste management, site assessment/remediation, treatment technologies, and human health risk issues. Hydrogen sulfide experience includes dozens of facilities, including landfills, coal-fired power plants, and paper mills.

 

 

Posted by Diane Samuels at 6:00 am

January 24, 2018

Odor management remains one of the most daunting tasks for any solid waste facility. Part I of Pat Sullivan’s series on odor management at solid facilities covered regulatory
requirements with two case studies detailing real-world examples of facilities battling odor issues. Part II of his series covers odor assessment, monitoring and
mitigation strategies.

Part I – Regulatory Requirements

Part II – Assessment, Monitoring and Mitigation

About the author, Pat Sullivan

 

 

Posted by Diane Samuels at 6:01 am
SCS Address

Corporate Headquarters

3900 Kilroy Airport Way Suite 300
Long Beach, CA 90806

Telephone

1 (800) 767-4727
1 (562) 427-0805 | FAX
Contact Us

Required Posting
Send us a message
×